RAE TECHNOLOGY PTE LTD
YellowTop Technical Specs
DUAL PURPOSE (STARTING & DEEP CYCLE) BATTERIES | ||||||
MODEL NUMBER | ||||||
PERFORMANCE |
|
|
|
|
|
|
Voltage | 12 | 12 | 12 | 12 | 12 | 12 |
Cold Cranking Amps BCI @ -18°C | 900 | 750 | 750 | 620 | 450 | 650 |
Cranking Amps BCI @ 0°C | 1125 | 870 | 870 | 770 | 575 | 770 |
Reserve Capacity (minutes) | 155 | 120 | 120 | 100 | 66 | 100 |
Capacity (C/20 rate) | 75 | 55 | 55 | 48 | 38 | 48 |
Internal Resistance (ohms) | 0.0025 | 0.0028 | 0.0028 | 0.003 | 0.0046 | 0.003 |
PHYSICAL SPECS |
|
|
|
|
|
|
Length (mm) | 325 | 255 | 255 | 237 | 236 | 237 |
Width (mm) | 166 | 174 | 175 | 170 | 128 | 172 |
Height (mm) | 238 | 199 | 199 | 195 | 226 | 196 |
Weight (kg) | 27.1 | 19.5 | 19.7 | 16.5 | 11.8 | 17.1 |
Post Type | SAE | GM | Dual SAE & GM | SAE | SAE & JAP | Dual SAE & GM |
BCI Group | 31 | 34 | 34/78 | 35 | 51 & 51R | 75/25 |
Product Spec Sheets
For printable product specification sheets, click on your battery choice above. The printable documents provide information on physical characteristics, performance, power, charging and shipping.
Charging Information:
Alternator:
13.65 to 15.0 volts, no amperage limit.
Battery charger:
13.8 to 15.0 volts, 10 amps maximum, 6-12 hours approximate.
Cyclic Applications:
14.7 volts, no current limit as long as battery temperature remains below 50°C (125°F). When current falls below 1 amp, finish with 3 amp constant current for 1 hour for YT S 5,5.and 2 amp constant current for 1 hour for all other types.
Rapid Recharge:
Maximum voltage 15.6 volts (regulated).
Maximum current: No limit as long as temperature <50°C (125°F).
Maximum recharge time: Charge until current drops below 1 amp.
Float charge:
13.2 to 13.8 volts, 1 amp maximum current, time indefinite (at lower voltage).
All limits must be strictly adhered to.
Safety Information :
Always wear safety glasses when working with batteries.
Always use a voltage regulated battery charger with limits set to the above ratings. Overcharging can cause the safety valves to open and battery gasses to escape, resulting in premature failure. These gasses are flammable! You cannot replace water in sealed batteries that have been overcharged. Any battery that becomes very hot or makes a hissing sound while recharging should be disconnected immediately.
Failure to fully charge a battery can result in poor performance and a reduction in capacity.